Taking work now — the first look is freeNAS drives posted in from anywhere in the UK, or handed in at ten drop-off pointsQuicker still, give us a ring:0800 6890668
NDRNAS Data Recovery 0800 6890668 Price my job
NDR / Manufacturers / Buffalo

LinkStation · TeraStation · E-codes · NAS Navigator · XFS

Buffalo NAS data recovery. E22 says format. Don't.

Buffalo's LinkStation and TeraStation units report faults as E-codes, on the display, by long and short flashes of the red LED, and in NAS Navigator, and the manual answers each with a corrective action written for a unit whose data is backed up elsewhere: reboot, reseat, replace, rebuild, and for E22, format the drive. If the files matter, the corrective action for every code is to power down, number the drives by bay, and send them. Underneath, a Buffalo is Linux with mdadm and XFS on most TeraStations or ext3 and ext4 on the older LinkStations, assembled from images on the bench; the Windows Storage Server TeraStations are NTFS over a hardware or software RAID and are read the same way. A single-drive LinkStation is £300 + VAT; a two-bay LinkStation or a TeraStation set is £500 + VAT upwards; four-bay and rack TeraStations from £1,250 + VAT, in writing after the free look.

Free first lookOne fixed figure in writingNo data, no bill on most jobsReturn postage paid

Rather talk it through? An engineer answers the bench line
0800 6890668

Power it down. Label each drive with its bay number. Do not rebuild, repair, initialise, reinstall or reset. A rebuild reads every sector of every surviving drive, and on a set with a second weak member it finishes what the first failure began. Nothing on the drives gets worse while the unit is off.

Models we see, family by family.

Which kind of unit is it →
Family Models Bays, OS, file system and layout
LinkStation, singleLS210, LS510, LS710, LS-CHL1 drive · ext4 or XFS
LinkStation, two-bayLS220, LS420, LS520, LS720, LS-WXL, Pro DuoRAID 0 or 1 · ext4 or XFS
TeraStation, desktopTS3010, TS3210, TS3410, TS5010, TS5210, TS5410, TS60002–8 bays · XFS · RAID 1/5/6
TeraStation, rackTS3020, TS5020, TS5810DN and rack variants4–8 bays · XFS
WSSTeraStation WS seriesNTFS on Windows Storage Server

What tends to go wrong on a Buffalo.

The E-codes and their remediesE14 array cannot be mounted; E15 bad sectors at a dangerous level; E16 drive not found; E22 drive cannot be mounted; E23 drive dropped from the array; E30 drive may be damaged; E04 firmware corrupt. The manual's answer to E22 is to format the drive; the bench's answer is to image it.
Rebuilds on aged setsA general pattern: a TeraStation RAID 5 that has run for years loses a drive, the rebuild reads every sector of the others, and the second failure is found. Every member imaged and the parity run on the images.
XFS after a power cutAn XFS log that did not replay leaves the array unmountable, E14, on a set of healthy drives. Replayed on the image, it mounts.
The first TeraStation, December 2004Buffalo has made these longer than almost anyone, and the older units arrive with tired power bricks and drives that have not been powered in years. Legacy units are read on the bench like any other.

Buffalo symptoms, and how long each gives you.

Not listed? Describe it on the form →
Packing it and posting it: power the unit down, write the bay number on each drive with a marker before it comes out, and send every drive from the set, including any SSD cache. Each drive travels in an anti-static bag inside its own padding, in a box with nothing able to move; the unit itself comes too if it holds an encryption key or a proprietary layout, and its power supply with it. Insure the parcel for what the files are worth rather than the price of the drives, and use a tracked service. The posting address is not printed anywhere on this site; it arrives by email in reply to the form, with a booking sheet to print; the sheet inside the parcel is what matches it to your enquiry when it is opened. Or hand the sealed parcel in at the nearest of ten drop-off points, your name on the outside and the sheet inside; say where you are on the form and it comes by email. We pay the postage home either way. The whole of it is written up on the guide to packing and posting.

What the message means on a Buffalo.

Describe yours to us →
What you see The usual reason Where that leaves you
E22A drive cannot be mounted; manual says formatDo not format; imaged and repaired on the image
E14Array cannot be mountedEvery member imaged; assembled from the superblocks
E04Firmware corrupt; data intactData arrays assembled without the firmware
Flashes: long then shortThe code counted in tens and unitsNAS Navigator shows it in words
Pool or volume degradedOne member lost; still readableCopy critical files; power down; no rebuild
Pool or volume crashed / unmounted / not activeToo many members lost, or file system damageEvery member imaged; assembled from the superblocks
Unit will not boot after an updateSystem partition or boot flash; data intactData arrays assembled without the OS
Drives shown as new in another unitForeign layout; the unit offers to installSay no; the order is read from the metadata

From the box arriving to your files going back.

Work we have closed →
01

Logged the day it lands, and the first look costs nothing Free

A case number goes on the parcel and a number on every drive the day it is opened, and an engineer settles what has actually happened before anything spins. The unit is examined on its own; each drive is assessed on our own equipment, never in a NAS that will try to rebuild. Back to you come two things together: a straight note of what is liftable and what is not, plus one figure, fixed and written down. Accept it, or decline and owe us nothing.

Nothing to pay for lookingA single figure, put in writingNo rebuilds, no repairs, no resets
02

The unit, and the drives, apart

The box and the disks are two different jobs. The unit is tested separately, because a dead power supply, a failed board or a bricked boot flash leaves the drives untouched more often than not. Each drive is then read on the bench: the ones that answer at full speed, and the weak or failed ones in clean air where they need head work. On units that hold an encryption key or a layout of their own, the unit is part of the data and is kept with it.

Unit and disks assessed separatelyFailing members to the clean bench
03

Every member imaged, once

Nothing is worked on live and nothing is rebuilt on the originals. Every drive in the set is imaged sector by sector, the weak ones head by head with the bad areas last, and the SSD cache with them where there is one. From then on the originals are not touched again.

Every drive, including the cacheWeak areas last
04

The set put back together, from the images

Order, chunk size, parity rotation and the reshape point are read from the drives' own metadata and the array is reassembled in software: mdadm and LVM under SHR, X-RAID and QTS pools; a ZFS pool imported read-only; Drobo's BeyondRAID zones reconstructed. The file system, Btrfs, ext4, XFS or ZFS, is repaired on the virtual volume, and encrypted volumes are unlocked there with the key you supply. Never on the originals.

Rebuilt in software, from imagesThe file system repaired on the virtual volume
05

You see the file list before you pay

What was recovered is listed for you first, and only then does a bill exist. Approve the list and it is invoiced; turn it down and it is not — and where nothing has come back, most jobs carry no charge at all. Recovered data travels home on fresh media bought in for your job, with the postage at our end. Your case is not closed until you have opened the files on a machine of your own.

No charge until you accept the figureFresh media, supplied with the job5–10 days at the bench

From the bench

  • Formatting on E22 is the fix when the data is backed up. When it is not, it is the end of it.
  • The flashes count the code: long for tens, short for units. Photograph the display or count the flashes before powering down.
  • TeraStations use XFS, which repairs well from its log on an image and badly from a rebuild on a weak drive.
  • Linux, mdadm, LVM and a file system. The maker's names for the layout sit on the kernel's own RAID, and every layer writes its description on every drive. The bench reads it from the images and needs nothing from the unit but its key.
  • A rebuild reads every sector of every survivor. On drives that have aged together it is where the second failure is found. The bench does the same arithmetic on images, which cannot drop out.
  • Label the bays. The metadata usually gives the order; the label makes it certain, and a set whose drives were swapped and initialised is a harder job.

One job, followed all the way through.

UK · NDR-2026-0545JOB LOGGED ✓

A TS3410 in RAID 5 showing E14 after a power cut, and a school's shared drive on it

The array would not assemble and the manual's next step was a rebuild. The unit was powered down instead. All four drives were imaged, one with bad sectors taken last, the array assembled from the superblocks on the images, and the XFS log replayed on the virtual volume before it was mounted read-only.

100% of it recovered6 days here, and back by post
Illustrative example — replace with a genuine case

What helps, and what harms.

Do this much first

  • Power down and label the bays
  • Send every drive, the unit and its supply
  • Tell us the OS version, the RAID mode and what was clicked
  • Find the encryption key if one was set

What sets us back

  • Rebuilding, repairing or resyncing
  • Reinstalling the OS or factory resetting
  • Moving the drives to another unit
  • Initialising drives the unit shows as new

Questions answered before you commit.

My Buffalo shows E22 and the manual says format. Should I?

Only if the data is backed up elsewhere. Formatting writes over the file system that holds it. If the files matter, power down and send the set.

What does E14 mean?

The RAID array cannot be mounted: too many drives dropped, or the metadata damaged. Assembled from images on the bench; do not rebuild.

Can you read a Windows Storage Server TeraStation?

Yes. It is NTFS over a RAID, imaged and assembled like any other set.

What does it cost?

£300 + VAT for a single-drive LinkStation; a two-bay LinkStation or a TeraStation set is £500 + VAT upwards; four-bay and rack TeraStations from £1,250 + VAT.

Nothing gets worse while it is powered down.

Looking at it is free. Back comes a list of what opened and what did not, together with a single price to finish, set down in writing while you are still free to say no. On most jobs an invoice only follows the data. Until that list reaches you, leave the unit off and the drives in their bays.

0800 6890668